Call us
+(374)77 435-777
Send inquiry

Pulsar-18

Vascular Intervention // Peripheral
Self-Expanding Stent System/0.018''/OTW

140 μm thin struts
 4F low profile
Clinically proven

140 μm thin struts - thinner than the leading brands1


 


Thinner struts for low Chronic Outward Force (COF)2







Thinner struts and lower COF make a difference:*

 

 

  • Lower risk of restenosis3
  • Reduced vessel injury and inflammation4
  • Faster endothelialization5


*As demonstrated in pre-clinical studies

 

 

 

 



1 mm stent oversizing at 90 days6





Clinically proven

 

 


Long term safety and efficacy (12 month data)
** FTLR - Freedom from Target Lesion Revascularization;
† PP - Primary Patency; ††A.L.L. - Average Lesion Length
 


Sufficient radial force for a long term vessel support,
even in calcified lesions


 


Exceptional clinical outcomes (12 month data)






Results from different trials are not directly comparable. Differences in outcomes may be the result of differences in protocol design, patient populations or other factors.

*Bail out group
 


Stent designed for SFA*

Multi-directional flexibility to conform to the natural vessel movement.

*Superficial Femoral Artery


Elongation


Low axial stiffness for high flexibility16




Bending


Peak-to-valley design and S-articulating connecting bars provide multi-directional flexibility and avoid fish scaling inmobile vessel architecture.17







 

Potential for safer, faster and simpler procedures than 6F

 

  • Clinically proven lower access site complication rates7
  • Shorter compression time7
  • 45% smaller puncture site area than 6F18
  • No need for a closure device

 

 


Stent deployment


One-handed stent release handle, ergonomically designed for a comfortable and stable handling.

 

 

 

 

 


 

 

 

 

 

Pulsar-18

 


Indicated for use in patients with atherosclerotic disease of the femoral and infrapopliteal arteries and for the treatment of insufficient results after percutaneous transluminal angioplasty.*

Technical Data

 

Pulsar-18 Stent
Catheter type OTW
Recommended guide wire 0.018"
Stent material Nitinol
Strut thickness 140 μm
Strut width 85 μm
Stent coating proBIO (amorphous silicon carbide)
Stent markers 6 gold markers each end
Sizes ø 4.0 - 7.0 mm; L: 204 - 200 mm
Proximal shaft 3.6 F, hydrophobic coating
Usable length 90 and 135 cm

 

Ordering Information

 

       
4.0 (4F)   377456 377457 377458 377459 377460 366808 366809 366810 366811 366812
5.0 (4F)   377461 377462 377463 377464 377465 366813 366814 366815 366816 366817
6.0 (4F)   377466 377467 377468 377469 377470 366818 366819 366820 366821 366822
7.0 (4F)   377471 377472 377473 377474 377475 366823 366824 366825 366826 366827

 

       
4.0 (4F)   377476 377477 377478 377479 377480 366828 366829 366830 366831 366832
5.0 (4F)   377481 377482 377483 377484 377485 366833 366834 366835 366836 366837
6.0 (4F)   377486 377487 377488 377489 377490 366838 366839 366840 366841 366842
7.0 (4F)   377491 377492 377493 377494 377495 366843 366844 366845 366846 366847

Related products


Astron

Astron

Read more
Pulsar-35

Pulsar-35

Read more
Pulsar-18 T3

Pulsar-18 T3

Read more
Astron Pulsar

Astron Pulsar

Read more